If your Alpha Intec 24X or Alpha Intec 28X boiler is displaying Error 43, the appliance has detected a loss of flame rectification. Although the burner may ignite briefly, the boiler cannot confirm a stable flame, so it shuts down as a safety precaution.
One of the most common causes is a damaged or worn flame sensing electrode. Fortunately, this is usually a straightforward repair when correctly diagnosed by a Gas Safe-registered engineer.
This guide explains what Error 43 means, how the flame rectification system works, common causes, diagnostic procedures, and the recommended repair.
What Does Error 43 Mean?
The flame rectification system constantly monitors the burner flame.
If the printed circuit board (PCB) cannot detect a flame signal within a specified time, the boiler immediately locks out and displays Error 43.
This prevents unburned gas from entering the combustion chamber and is an essential safety feature.
How Flame Rectification Works
Many homeowners don’t realise the boiler continuously checks that combustion is taking place.
The flame electrode sends a tiny electrical current through the flame back to the PCB.
If this current disappears, the boiler assumes ignition has failed and immediately shuts the gas valve.
This entire process happens within seconds every time the boiler starts.
Common Causes of Alpha Error 43
Although the flame electrode is the most common fault, several components can trigger Error 43.
| Possible Fault | Likelihood | Recommended Action |
|---|---|---|
| Damaged flame sensing electrode | Very Common | Replace electrode |
| Dirty burner | Common | Clean burner |
| Loose ignition lead | Common | Inspect connections |
| Faulty spark generator | Less Common | Test output |
| PCB fault | Rare | Confirm after other tests |
| Gas supply problem | Rare | Check inlet pressure |
Symptoms You May Notice
Before Error 43 appears, customers often report:
- Boiler attempts to ignite several times
- Heating stops unexpectedly
- Hot water becomes intermittent
- Clicking sounds during ignition
- Boiler resets temporarily before the fault returns
- Error 43 appearing more frequently over time
Recognising these symptoms early can help prevent a complete heating breakdown.
Step-by-Step Diagnosis
Step 1 – Inspect the Flame Electrode
Remove the combustion cover and inspect the flame sensing electrode.
Pay particular attention to:
- Cracks
- Carbon deposits
- Incorrect positioning
- Broken ceramic insulation
- Electrode length
The Alpha flame electrode is unusually long and can snap due to repeated heat cycles or accidental damage during servicing.
Step 2 – Replace the Electrode
If damaged, replace using:
Alpha OEM Part Number: 1258295
Always use genuine manufacturer parts whenever possible.
After installation, ensure the electrode gap and position match the manufacturer’s specifications.
Step 3 – Check the Ignition Lead
Inspect the ignition cable for:
- Burn marks
- Loose connections
- Damaged insulation
- Moisture ingress
A poor electrical connection can interrupt flame rectification.
Step 4 – Test Flame Signal
Using the manufacturer’s recommended test procedure, verify that the flame rectification current falls within specification.
Low flame current may indicate:
- Electrode contamination
- Burner contamination
- Earth faults
- PCB issues
Engineer’s Tip
When replacing the flame electrode, always inspect the burner and combustion chamber simultaneously.
Carbon deposits can affect flame stability and reduce the effectiveness of the new electrode.
Taking an extra few minutes during the repair often prevents repeat call-outs.
Common Mistakes to Avoid
Avoid these common errors:
- Replacing the PCB before checking the electrode
- Reusing damaged seals
- Ignoring loose earth connections
- Not checking combustion after repair
- Using non-genuine ignition components
Systematic diagnostics always save time.
Can Homeowners Fix Error 43?
No.
Although the flame electrode appears accessible, it forms part of the combustion system.
Only a Gas Safe registered engineer should remove combustion components or carry out ignition system repairs.
Preventing Future Error 43 Faults
Regular annual servicing significantly reduces ignition faults.
During a boiler service, engineers should inspect:
- Flame electrode condition
- Burner cleanliness
- Ignition leads
- Combustion readings
- Heat exchanger
- Condensate trap
- Fan operation
Preventative maintenance is considerably cheaper than emergency repairs.
Why Choose Certificates4UK Ltd?
Since 2011, Certificates4UK Ltd has repaired thousands of domestic boilers throughout Surrey.
We regularly diagnose and repair:
- Alpha
- Worcester Bosch
- Vaillant
- Ideal
- Baxi
- Viessmann
- Vokera
- Glow-worm
Our engineers carry many common ignition components, allowing many repairs to be completed during the first visit.
Quick Reference
| Boiler | Fault Code | Common Cause |
|---|---|---|
| Alpha Intec 24X | Error 43 | Flame electrode |
| Alpha Intec 28X | Error 43 | Flame electrode |
| Alpha E-Tec | Ignition fault | Electrode or ignition |
Frequently Asked Questions
Can I reset Error 43?
Resetting the boiler may temporarily clear the fault, but if the underlying problem remains, the error will return.
Is Error 43 dangerous?
The fault itself is a safety shutdown designed to prevent unsafe boiler operation. However, repeated ignition failures should always be investigated by a qualified engineer.
How long does the repair take?
In most cases, replacing a faulty flame sensing electrode takes less than an hour once the fault has been diagnosed.
What is the replacement part number?
Alpha OEM Flame Electrode – Part Number: 1258295
Related Services
- Gas Safety Certificate (CP12)
- Boiler Servicing Surrey
- Boiler Repairs Surrey
- The Energy Performance Certificate (EPC)
- The Electrical Installation Condition Report (EICR)
Useful links
Contact Certificates4UK Ltd
Need a reliable Gas Safe engineer for boiler repairs, safety checks, or certification? We’re here to help.
We cover:
Molesey • Walton • Woking • Cobham• Weybridge • Sunbury-on-Thames • Surrey • London
Before replacing any parts or booking costly work, let one of our qualified engineers carry out a professional inspection to save you time and money.
Booking Options:
- 🌐 Book Online – Simple, quick, and available 24/7
- 📞 Call: 07596 076700 or 07869 520044
- 📧 Email: info@certificates4uk.co.uk
📍 Proudly serving Molesey, Surrey, and London, we specialise in:
Boiler repairs, Gas Safety Certificates (CP12), Installation, plumbing, EICR testing, EPC inspections, and full property compliance.
⭐ Established in 2011, C4UK has been providing professional heating and property compliance services across Surrey and London. 150+ five-star reviews, Certificates4UK Ltd is the trusted choice for safe, professional, and cost-effective heating services.


Leave a Reply