Simple graphic showing Ravenheat WH80/90 boiler fault codes with fixes

Ravenheat WH80/90 Boiler Fault Codes: Common Problems & How to Fix Them

 Common Ravenheat Fault Codes

As Ravenheat WH80/90 boilers are now coming out of warranty, we’re seeing more of them needing repairs across Surrey and London. These budget-friendly models are often installed quickly and with minimal attention to detail, which means poor water quality and common faults become major issues over time.

Here at Certificates4UK Ltd, we’ve put together a quick guide to the most frequent fault codes on Ravenheat WH80/90 boilers—and what they mean for your home heating.

 Common Ravenheat Fault Codes

01E – No Flame

🔍 Cause: Boiler fails to ignite.

✅ Checks: Gas supply, overheat stat, gas valve, spark generator, and ignition electrodes.

02E – Pump Circulation Fault

🔍 Cause: Circulation issue in central heating system.

✅ Fix: Check if the pump is spinning and ensure there is no air trapped in the system.

03E / 04E – Sensor Faults

🔍 Cause: Faulty temperature sensors for central heating (CH) or domestic hot water (DHW).

✅ Fix: Replace damaged CH or DHW sensors to restore proper functionality.

08E – Low Water Pressure

🔍 Cause: Insufficient pressure in the system.

✅ Fix: Top up the boiler pressure via the filling loop. Normal pressure should be between 1.0–1.5 bar when cold.

10E – High Water Pressure

🔍 Cause: Pressure exceeding safe levels.

✅ Fix: Make sure the expansion vessel is properly charged and system pressure stays below 1.8 bar.

⚠️ This issue can be frustrating and often comes from a neglected expansion vessel or system overfilling.

 Why Water Quality Matters

Ravenheat boilers, especially the WH80/90 models, are often installed with little consideration for water treatment. Over time, sludge and scale build-up can damage key components and trigger these fault codes.

💡 Solution: Book a professional power flush or system clean to restore efficiency and reduce recurring faults.

 Need Help with a Ravenheat Boiler?

Whether you need a diagnosis, repair, or full service, our Gas Safe engineers at Certificates4UK Ltd are ready to help. We cover Kingston, Richmond, Wimbledon, West Molesey, and all nearby areas.

We’ve repaired dozens of Ravenheat WH80/90 boilers and can often identify issues on the first visit.

 Contact Us Today

If your Ravenheat boiler is showing a fault code or not performing as it should, don’t delay.

👉 Call Certificates4UK Ltd now or book online for fast, affordable boiler repair.

•  Online:

📞 Call: 07869 520044 or +44 7596 076700

•  Emailinfo@certificates4uk.co.uk or certificates4uk@gmail.com

Certificates4UK Ltd – Keeping Homes Warm Across Surrey & London

author avatar
Eliza Żmuda Digital & Operations Manager
Digital & Operations Manager at Certificates4UK. Responsible for website management, digital marketing, customer enquiries, and booking coordination.

Leave a Reply

Discover more from Certificates4UK

Subscribe now to keep reading and get access to the full archive.

Continue reading